Basic Info.
Model NO.
                             CO2 fractional laser machine
                         Laser Mode
                             Lower Order
                         Laser Wavelength
                             10.6μm
                         Beam Divergence Angle
                             4mrad
                         Focused Spot Diameter
                             ≤0.4mm
                         Pulse Width
                             0.02-0.99s
                         Aiming Beam
                             Infrared Ray (650nm, 2MW)
                         Beam Delivery
                             7 Joint-Articulated Arms
                         Cooling System
                             Inside-Circle Coolant
                         Humidity
                             <80%
                         Air Pressure
                             86kpa-106 Kpa
                         Electromagnet
                             No Electromagnet Interrupt
                         Preheating-Time
                             >5min
                         Other Working Environment
                             No Obvious Shaking or Airflow
                         Transport Package
                             Carton
                         Specification
                             144x69x74CM
                         Trademark
                             GOMECY
                         Origin
                             Beijing
                         Production Capacity
                             50000/Year
                         Product Description
 
    Introduction of instrument:
   Introduction of instrument:   The medical products (CO2 fractional laser therapy instrument) are widely used in general surgery,dermatology, gynecology, ENT,
paediatrics, urology and other treatment, especially being suitable for cosmetology, eye removal, perioral wrinkles, acne scars,
surgical scars, traumatic scars and benign skin neoplasm.
CO2 fractional laser therapy device is designed and manufactured in full compliance with the relevant national standard GB11748- 1995:
"Carbon dioxide laser treatment machine", national standard GB7247.1-2001 "Safety of laser products Part 1: Equipment Classification Requirements and User's Guide ", "national Standard GB9706.1-1995 " medical Electrical equipment Part I: General Requirements for
Safety" and GB 9706.20 -2000 "medical electrical equipment - Part 2: Diagnostic and therapeutic laser equipment safety requirements "
requirements.
This manual is designed for medical and technical staff to make better use of carbon dioxide laser treatment. In this manual you will find
how to installation, commissioning, operation and maintenance of carbon dioxide laser treatment and other details of the important information.
 
    
    
    
    
   | Working mode: | Single pulse, continuous pulse, repeated pulse Output power 40w (adjustable) | Aiming beam: | infrared ray (650nm, 2mw) | 
| Input power: | 450VA | Beam Delivery: | 7 joint-articulated arms | 
| Laser type: | Sealed-off CO2 laser tube/ RF laser tube | Cooling system | Inside-circle coolant | 
| Laser mode: | Lower order | Humidity: | <80% | 
| Laser wavelength: | 10.6μm | Air pressure: | 86KPA-106 KPA | 
| Scan Pattern: | triangle/square/rectangle/diamond /line/round | Input voltage: | AC220V±10%, 50Hz AC110V±10%,60Hz | 
| Beam divergence angle: | 4mrad | Electromagnet: | No electromagnet interrupt | 
| Focused spot diameter: | ≤0.4mm | Preheating-time: | >5min | 
| Pulse width: | 0.02-0.99s | Other working environment: | No obvious shaking or airflow | 
 
    
    
    
    
    
    
    
    
    
    
    
    
    
                     
 
                        




 
                                     
                                     
                                     
                                     
                                    